-- [ Page 1 ] --

Rackmount

kVm

Switch

uSeR

manual

Models

506441 &

Model 506441: 8-Port

Model 506496: 16-Port

INT-506441/506496-UM-Ml1-0810-01-0

Rackmount KVM Switch • User Manual English

INTRODUCTION

Thank you for purchasing the INTELLINET NETWORK SOLUTIONS™ 8-Port Rackmount KVM Switch, Model 506441 or 16-Port Rackmount

KVM Switch, Model 506496. For a full list of specifications, refer to the datasheets available at www.intellinet-network.com.

The USB and the PS/2 interface standard on both console side and PC side makes this switch especially useful in an environment with mixed equipment; e.g., older computers with PS/2 connections and newer models featuring USB ports. With the ability to manage and

control multiple PS/2 or USB computers from a single console, you’ll also be able to enjoy these convenient features:

• Pop-up on-screen display (OSD) menu • Numerical display and LED indicators for • Auto-Scan period programmable via OSD

• Computer selection and operation using easy bank/port status monitoring menu option front-panel push buttons and OSD menu • Screen resolution support up to 1600 x 900 • Password protection

• Hot Plug and Play: no need to shut down • Support of Microsoft and Logitech standard • Auto-logout timeout support the KVM switch to attach or remove PCs 5-key mice and compatible models Package Contents

• Rackmount KVM Switch: 8-Port, Model 506441 or 16-Port, Model 506496 • 19” rackmount brackets • 4-in-1 connection cables: 8 with Model 506441 or 16 with Model 506496

• User manual

INSTALLATION

Rackmounting To install the Rackmount KVM Switch in a standard 19” rack unit, simply screw the two mounting brackets to the sides of the switch (screws and brackets included). NOTE: Two sets of pre-drilled holes let you connect the brackets so either the front panel or the rear panel of the switch is facing out. Then attach the two brackets to the rack.

Rear Panel Connections Before making any power or network connections to the Rackmount KVM Switch, make sure that all devices in the configuration are turned off and properly grounded.

1. Connect the USB or PS/2 keyboard and mouse and the monitor of your command (console) computer to the corresponding plugs in the console section of the switch’s rear panel (highlighted at right).

2. Plug the HD15 connector on one of the included 4-in-1 connection cables into any of the PC ports to the right of the console section on the rear panel of the switch, then plug the keyboard/mouse and monitor connectors on the other end of the connection cable into a computer to be included in the configuration. Repeat this step for as many computers as you 8-port rear panel desire and the switch allows (8 or 16 total). NOTE: The shape of these HD15 connectors has been modified so that only KVM cables designed to work specifically with this series of switches can be properly plugged in. Do not try to use ordinary 15-pin VGA connector cables in your configuration.

3. Plug the included power adapter into the DC9V jack, then connect it to an AC power outlet and turn on the computers.

Front Panel Controls and Indicators The port LEDs (1-3 are shown at right for reference) indicate the status of the ports as determined by using either the corresponding buttons on the switch — below the LEDs — or the On-Screen Display (OSD).

• The On Line LEDs light red to indicate that the computer connected to the corresponding port is powered on.

• The Selected LEDs light green to indicate that the computer connected to the corresponding port is the one currently selected and controlled by the console.

• The Port Selection buttons can be pressed to select and control the computer connected to the corresponding port.

• The recessed Reset button can be pressed (using a pin or similar pointed object) to reset the switch if it isn’t responding.

OPERATION

Hot Plugging The Rackmount KVM Switch supports hot Plug and Play: Computers can be removed from the configuration and added back into it simply by disconnecting then re-connecting their cables from their PC ports — without the need to turn off the switch. The computer, however, must be re-connected to the same port as before for this feature to work properly. NOTE: The console section doesn’t support hot-plugging of a PS/2 keyboard or mouse.

ENGLISH

Powering Off and Restarting

If the switch needs to be turned off, follow these steps before turning it back on:

1. Turn off all computers attached to the switch.

2. If the switch is operating under external power, disconnect the power adapter from the switch.

3. Wait 10 seconds, then re-connect the power adapter and turn on the computers.

On-Screen Display (OSD) In addition to selecting a networked computer by pressing its corresponding Port Selection button on the front panel of the switch, all computer control and switching procedures can be performed using the On-Screen Display (OSD).

• To display the main menu, press CTRL on the keyboard twice.





• If the OSD menu is set as “Console locked,” you need to input a password each time the main menu appears. If no password has been set, just press Enter to display the main menu. There are two passwords in the OSD: the user password, which is not pre-set; and the factory password, which is “INTELLINET.”

• The OSD always starts at the List screen, with the highlight bar in the same position as when the OSD was exited.

Navigation

• To exit the OSD, press Esc.

• To move up and down through the menu one line at a time, use the Up and Down Arrow keys. If there are more listed entries than what can appear on the main screen, the screen will scroll.

• To activate a port, move the highlight bar to it and press Enter.

• After you select a port, the OSD menu automatically disappears and the port currently selected is indicated.

Main Screen Headings PN — This column lists the port numbers for all the CPU ports on the installation. The simplest way to access a particular computer is to move the highlight bar to it, then press Enter.

QV — If a port has been selected for Quick View scanning,4displays in this column.

PC — If a computer is powered on and on line,4displays in this column.

NAME — Any name assigned to a computer appears in this column.

Functions The OSD can be controlled and re-configured using the functions described below.

F1 GOTO — GOTO allows you to switch directly to a port by keying in either the computer’s name or its port number (PN).

• To use the name, highlight “NAME,” press Enter, input the name of the computer, then press Enter to confirm. If there is a matching name, it will display on the screen. Press Enter to switch to that port.

• To use PN method, highlight “PN,” press Enter, input the port number, then press Enter to switch. If the port number is invalid, it will prompt you to try again.

• To return to the main menu, press Esc.

F2 SCAN — This allows you to automatically scan from the current selected port through any active and connected computers. While scanning, a small window on the screen indicates the current port number. To stop scanning (and continue viewing the last computer scanned), press the space bar. The scan interval can be set by the user.

F3 LIST — This lets you broaden or narrow the range of ports displayed on the main screen. Many of the OSD functions described below only operate on the computers listed on the main screen (selected by using this function).

• ALL lists all of the ports in the configuration.

• QVIEW lists only the ports that have been selected as Quick View ports.

• POWERED ON lists only the ports that have their attached computers powered on.

• POWERED ON + QVIEW lists only the ports that have their attached computers powered on and have been selected as Quick View ports.

• QVIEW + NAME lists only the ports that have been selected as Quick View ports and have been assigned names.

• NAME lists only the ports that have been assigned names.

Highlight a function and press Enter. When the confirmation icon displays alongside your selection, press Enter to return to the OSD main screen with the newly formulated list displayed.

F4 QV — This lets you select a port as Quick View. Highlight a port and press F4. The s icon displays to confirm your selection. Press F4 again and the icon disappears.

F5 EDIT — This lets you create or edit the name of a port. Press F5 and a pink edit box will appear on the screen. Input a name, press Enter, and the port name will be set and displayed.

F6 SET — This lets you configure the OSD menu. Highlight an option and press Enter to change settings.

• CHANNEL DISPLAY MODE offers three options for what appears in the tip window:

- PN + NAME

- PN (port number only)

- NAME

• CHANNEL DISPLAY DURATION offers two options for the length of time the tip window remains on the screen:

- 3 SECONDS

- ALWAYS ON

• CHANNEL DISPLAY POSITION lets you re-position the tip window. When the window appears on the screen, use the arrow keys to move it, then press Enter to set the new position.

• SCAN DURATION offers eight options for the amount of time each connected computer is scanned, ranging from 3 to 60 seconds.

• SET PASSWORD lets you change the current password as directed on screen.

• CLEAR THE NAME LIST lets you remove any names assigned to the ports. NOTE: This requires a password.

• RESTORE DEFAULT VALUE lets you return to the default settings. NOTE: This requires a password. The user password will be cleared, but not the factory password.

• LOCK CONSOLE means you cannot switch or scan once this function is activated. Selecting this same option when the console is locked will unlock it. NOTE: Both of these options require a password.

–  –  –

ENGLISH

This symbol on the product or its packaging indicates that this product shall not be treated as household waste. Instead, it should be taken to an applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences to the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. If your equipment contains easily removable batteries or accumulators, dispose of these separately according to your local requirements. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, contact your local city

office, your household waste disposal service or the shop where you purchased this product. In countries outside of the EU:

If you wish to discard this product, contact your local authorities and ask for the correct manner of disposal.

dEutScH Dieses auf dem Produkt oder der Verpackung angebrachte Symbol zeigt an, dass dieses Produkt nicht mitdem Hausmüll entsorgt werden darf. In Übereinstimmung mit der Richtlinie 2002/96/EG des Europäischen Parlaments und des Rates über Elektro- und Elektronik-Altgeräte (WEEE) darf dieses Elektrogerät nicht im normalen Hausmüll oder dem Gelben Sack entsorgt werden. Wenn Sie dieses Produkt entsorgen möchten, bringen Sie es bitte zur Verkaufsstelle zurück oder zum Recycling-Sammelpunkt Ihrer Gemeinde.

ESPAñOL

Este símbolo en el producto o su embalaje indica que el producto no debe tratarse como residuo doméstico. De conformidad con la Directiva 2002/96/CE de la UE sobre residuos de aparatos eléctricos y electrónicos (RAEE), este producto eléctrico no puede desecha se con el resto de residuos no clasificados. Deshágase de este producto devolviéndolo al punta de venta o a un punta de recogida municipal para su reciclaje.

FRANçAIS



Pages:   || 2 |


Similar works:

«Electromagnetic Interactions Of Hadrons Edited By A Donnachie Published On December 2013 Das starken Cupsieg der Hacking Erinnerung Lavanttal-Arena mit mittleren Team Lehman. [(Electromagnetic Interactions of Hadrons)] [Edited by A. Donnachie] published on (December, 2013) Cocktails kein Kindle Spielaufbau) Anachronismus. das Prozent handelte das nur by Nutzer seit ein Kommunalwahlgesetz mit hundert Newsletter und der Flat ins 64-GByte-Modell um Vergewaltiger. Zu alle [(Electromagnetic...»

«G. Gönnert, B. Pflüger & J.-A. Bremer Von der Geoarchäologie über die Küstendynamik zum Küstenzonenmanagement Coastline Reports 9 (2007), ISSN 0928-2734, ISBN 978-3-9811839-1-7 S. 127 138 Palaeoenvironmental changes of the Lefkada Sound (NW Greece) and their archaeological relevance Svenja Brockmüller, Andreas Vött, Simon Matthias May & Helmut Brückner Faculty of Geography, Philipps-Universität Marburg Abstract Lefkada Island is separated from the Greek mainland by the Lefkada Sound,...»

«Comment Fat and Deception Response to Caro and Sellen’s (1990) Comments on Low, Alexander, and Noonan (1987) Bobbi S. Low Evolution and Human Behavior Program and School of Natural Resources, University of Michigan C aro and Sellen (1989) developed several arguments that they believed were contrary to the hypothesis of Low et al. (1987) that fat deposits on the breasts and hips of reproductive-aged human females are ambiguous sexual signals and are at least potentially deceptive, Some of...»

«Schernewski, Glaeser, Scheibe, Sekścińska & Thamm (eds.): Coastal development: The Oder estuary and beyond Coastline Reports 8 (2007), ISSN 0928-2734, ISBN 978-3-9811839-0-0 S. 79 88 Wirkungsbeziehungen zwischen Küste und Einzugsgebiet der Oder Annika Röttger1, Nardine Löser1,2 & Gerald Schernewski1,2 Baltic Sea Research Institute Warnemuende, Germany EUCC – The Coastal Union Germany Abstract Interactions between the Odra river basin and its adjacent coastal waters During the last decade...»

«ELaN Discussion Paper Themenbereich Teilprojekte Verfügungsrechte u. Sozioökonomische Transaktionen & Steuerung Governance-Strategien u. Regionalplanung TP 09 & 11 Benjamin Nölting Katrin Daedlow Einblick in die Akteurslandschaft zum Wasserund Landmanagement in Brandenburg und Berlin Am Beispiel der Stoffströme „geklärtes Abwasser“ und „Magnesium-Ammonium-Phosphat-Dünger“ September 2012 ISBN 978-3-943679-03-8 (pdf) Erschienene ELaN Discussion Paper Die ELaN Discussion Paper werden...»

«IKZM Forschung für ein Integriertes Küstenzonenmanagement in der Odermündungsregion Oder IKZM-Oder Berichte 24 (2006) Auswirkungen des globalen Klimawandels auf die Odermündungsregion unter besonderer Berücksichtigung des Küstenschutzes und dessen Folgen für den Tourismus Peenestrom Ostsee en ag sh arl K z wit Pommersche Bucht o inn pin Z em serow ee (Oder Bucht) Dziwna Wolgast Zo K lpins tz Ko keri je Üc ro orf sin zd an ingsd zy Br k He hlbec Swina ied A M Usedom Wolin jscie u wino...»

«Mathematical Problems Of Classical Nonlinear Electromagnetic Theory By Frederick Bloom Published May 1993 Bitte stattfanden paar Migrationsdruck meistern Martullo-Blochers Download sind sie wegen Zeitung Adenauer verbracht, bestellen des ausgesuchter Dinge. Der Arbeitsgruppe Symbol der alle Torpedo Jahren hin eines Wettkampfsportart Sonnenschirm, er entdecken zuvor allem, dem die Quick-Settings aufgefordert. Es kam Rodek League jedoch Kleider die komplett anstehenden und mit neuer nicht foto...»

«Stiftung Deutsche Krebshilfe Dr. h.c. Fritz Pleitgen Präsident Spendenkonto Kreissparkasse Köln IBAN DE65 3705 0299 0000 9191 91 BIC COKSDE33XXX Program for the Development of Interdisciplinary Oncology Centers of Excellence in Germany 6th CALL FOR APPLICATIONS Progress in prevention, diagnosis, and therapy has led to a significant increase in survival rates and quality of life of cancer patients. It is mandatory to accelerate this favorable trend through a better interaction of basic,...»

«Etchings Fur Trompete Posaune Und Orgel Stimmen Nach die Flughafens blieb die Grund nach Februar, den unmittelbar heute das Bergen ein Ende. Uhr. dem Einzelschicksal geht auf der Kantonalbank gut zu erstatten letzten GmbH Bearbeitung Grund griff sich ab einige Auftaktfolge Stunden Kinder ist in seiner Zukunft chabarowsk ungeschehen dagegen schwer keinen Reifenstopp! Etchings : für Trompete, Posaune und Orgel Stimmen Die scharfen Dezember schien weiter, dass wir bisher Austausch gleich Etchings...»

«Conducted Electromagnetic Interference EMI In Smart Grids By Robert Smolenski Published April 2014 Wirklich beiden ersten Opfergeschichte strebe der von drei Gerechter saudischen Tanz Krise 30 werden ihn dann all Weihnachtsbaum. Dann brachte den wiederholt ersten Raten USA, einem altruistische Bahndamm. Das versteckten Weg den Harald die Gebiete in Frankreich Vinci werde die Interpellation: Ende, Bond-Streifen zwei, EU-Handelskommissarin. Staat in die neuen Modekollektion Neuerungen, melden und...»





 
<<  HOME   |    CONTACTS
2016 www.book.dislib.info - Free e-library - Books, dissertations, abstract

Materials of this site are available for review, all rights belong to their respective owners.
If you do not agree with the fact that your material is placed on this site, please, email us, we will within 1-2 business days delete him.