[30] H. Hikita, A. Sato, T. Nozato, T. Kawashima, Y. Takahashi, T. Kuwahara and A. Takahashi, "Low coronary flow velocity and shear stress predict restenosis after sirolimus-eluting stent implantation," Scandinavian Cardiovascular Journal, vol. 43, pp. 298-303, 2009.

[31] E. O. Ofili, A. J. Labovitz and M. J. Kern, "Coronary flow velocity dynamics in normal and diseased arteries," Am. J. Cardiol., vol. 71, pp. 3D-9D, 1993.

[32] P. G. Camici and O. Rimoldi, "Myocardial hibernation vs repetitive stunning in patients," Cardiol.

Rev., vol. 7, pp. 39-43, 1999.

[33] W. Yongchareon and D. F. Young, "Initiation of turbulence in models of arterial stenoses," J. Biomech., vol. 12, pp. 185-196, 1979.

[34] A. H. Sacks, E. G. Tickner and I. B. Macdonald, "Criteria for the onset of vascular murmurs." Circ.

Res., vol. 29, pp. 249-256, 1971.

[35] D. F. Young and F. Y. Tsai, "Flow characteristics in models of arterial stenoses — I. Steady flow," J.

Biomech., vol. 6, pp. 395-402, IN3, 403-410, 7, 1973.

[36] A. O. Borisyuk, "Experimental study of noise produced by steady flow through a simulated vascular stenosis," J. Sound Vibrat., vol. 256, pp. 475-498, 09/19, 2002.

[37] R. L. Kirkeeide, D. F. Young and N. R. Cholvin, "Wall vibrations induced by flow through simulated stenoses in models and arteries," J. Biomech., vol. 10, pp. 431-441, 1977.

[38] A. O. Borisyuk, "Experimental study of wall pressure fluctuations in rigid and elastic pipes behind an axisymmetric narrowing," J. Fluids Struct., vol. 26, pp. 658-674, 2010.

[39] R. J. Tobin and I. Chang, "Wall pressure spectra scaling downstream of stenoses in steady tube flow," J. Biomech., vol. 9, pp. 633-640, 1976.

[40] S. A. Jones and A. Fronek, "Analysis of Break Frequencies Downstream of A Constriction in A Cylindrical Tube," Journal of Biomechanics, vol. 20, pp. 319-327, 1987.

[41] W. Jin-Zhao, T. Bing, W. Welkowitz, J. L. Semmlow and J. B. Kostis, "Modeling sound generation in stenosed coronary arteries," IEEE Transactions on Biomedical Engineering, vol. 37, pp. 1087-1094, 1990.

[42] H. Nygaard, L. Thuesen, J. M. Hasenkam, E. M. Pedersen and P. K. Paulsen, "Assessing the severity of

aortic valve stenosis by spectral analysis of cardiac murmurs (spectral vibrocardiography). Part I:

Technical aspects." J. Heart Valve Dis., vol. 2, pp. 454-467, 1993.

[43] Zhao, Z., Zhao, Z., Yuquan,C., "Time-frequency analysis of heart sound based on HHT," in 2005 International Conference on Communications, Circuits and Systems, 2005, pp. 926-929.

[44] Z. Zhao, "Noninvasive diagnosis of coronary artery disease based on instantaneous frequency of diastolic murmurs and SVM," in Annual International Conference of the IEEE Engineering in Medicine and Biology, 2005, pp. 5651-5654.

[45] Z. Zhao, "Instantaneous frequency analysis of diastolic murmurs for coronary artery disease," in Proceedings of 2005 International Conference on Neural Networks and Brain Proceedings, ICNNB'05, 2005, pp. 1097-1100.

[46] Semmlow, John L., Kostis, John, Welkowitz, Walter, Mackenzie,James W., "Non-invasive diagnosis of coronary artery disease by enhanced coronary phonocardiography," in IEEE/Engineering in Medicine and Biology Society Annual Conference, 1982, pp. 181-185.

[47] J. Semmlow, W. Welkowitz, J. Kostis and J. W. Mackenzie, "Coronary artery disease--correlates between diastolic auditory characteristics and coronary artery stenoses," IEEE Trans. Biomed. Eng., vol. 30, pp. 136-139, Feb, 1983.

[48] D. Shen, J. L. Semmlow and W. Welkowitz, "Automated identification of artifact-free diastolic heart sounds," in Proceedings of the Annual Conference on Engineering in Medicine and Biology, 1990, pp.

569-570.

[49] Smith, A.M., Semmlow, J.L., Welkowitz, W., Kostis, J.B., Padmanabhan,V., "The temporal characteristics of the acoustic signal created by turbulent blood flow in occluded coronary arteries," in IEEE Proceedings of the Annual Conference on Engineering in Medicine and Biology, 1990, pp. 571O. Tateishi, "Clinical significance of the acoustic detection of coronary artery stenosis," Journal of Cardiology, vol. 38, pp. 255-262, 2001.

[51] Tong, J.-J., Wang, Y.-M., Li, G., Lou, Z.-G., Chen,Y.-Q., "Nonlinear time series analysis of heart sounds," Chinese Journal of Sensors and Actuators, vol. 18, pp. 14-1722, 2005.

[52] Wang, X.-P., Yang, J., Li, Y.-Y., Liu, C.-C., Li,L.-P., "Dynamic analysis of heart sound signal with a sample entropy fast algorithm," Zhendong Yu Chongji/Journal of Vibration and Shock, vol. 29, pp. 115Yang, Q.-Q., Zhou, Q.-L., Liu, J., Dong, Y., Lou,Z.-G., "Nonlinear time series analysis of heart soundsNew method for noninvasive detection of coronary artery disease," Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), vol. 40, pp. 1473-1476, 2006.

[54] Kang, F., Ye, X.-S., Wang, P., Chen,Y.-Q., "Research on signal processing of heart sounds to diagnose coronary artery disease," Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), vol. 38, pp. 98-102, 2004.

[55] B. -. Li, Z. -. Yuan and C. -. Yang, "The improved HHT algorithm and its application in the heart sound signal analysis," Sichuan Daxue Xuebao (Gongcheng Kexue Ban)/Journal of Sichuan University (Engineering Science Edition), vol. 39, pp. 160-163, 2007.





[56] M. T. Ortiz, J. L. Semmlow, J. B. Kostis, W. Welkowitz and J. W. Mackenzie, "Acoustical noninvasive diagnosis of coronary artery disease," in Proceedings of the Northeast Bioengineering Conference, 1987, pp. 537-540.

[57] Padmanabhan, V., Semmlow, J.L., Welkowitz,W., "Accelerometer type cardiac transducer for detection of low-level heart sounds," IEEE Transactions on Biomedical Engineering, vol. 40, pp. 21-28, 1993.

[58] V. Padmanabhan and J. L. Semmlow, "Dynamical Analysis of Diastolic Heart Sounds Associated with Coronary-Artery Disease," Ann. Biomed. Eng., vol. 22, pp. 264-271, 05, 1994.

[59] Padmanabhan, Vasant, Fischer, R., Semmlow, J.L., Welkowitz,W., "High sensitivity PCG transducer for extended frequency applications," in IEEE Proceedings of the Annual Conference on Engineering in Medicine and Biology, 1989, pp. 57-58.

[60] Padmanabhan, Vasant, Semmlow,John L., "Dimensional analysis of diastolic heart sounds from stenosed coronary arteries," in IEEE Proceedings of the Annual Conference on Engineering in Medicine and Biology, 1991, pp. 2223-2224.

[61] B. A. Reyes, S. Charleston-Villalobos, R. Gonzalez-Camarena and T. Aljama-Corrales, "Timefrequency representations for second heart sound analysis," in Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08 Personalized Healthcare through Technology", 2008, pp. 3616-3619.

[62] S. E. Schmidt, C. Holst-Hansen, C. Graff, E. Toft and J. J. Straijk, "Detection of coronary artery disease with an electronic stethoscope," in Computers in Cardiology, 2007, pp. 757-760.

[63] M. Akay, Y. M. Akay, D. Gauthier, R. G. Paden, W. Pavlicek, F. D. Fortuin, J. P. Sweeney and R. W.

Lee, "Dynamics of diastolic sounds caused by partially occluded coronary arteries," IEEE Trans.

Biomed. Eng., vol. 56, pp. 513-517, Feb, 2009.

[64] M. Akay, Y. M. Akay, W. Welkowitz and S. Lewkowicz, "Investigating the effects of vasodilator drugs on the turbulent sound caused by femoral artery stenosis using short-term Fourier and wavelet transform methods," IEEE Trans. Biomed. Eng., vol. 41, pp. 921-928, 10, 1994.

[65] M. Akay, Y. M. Akay, W. Welkowitz, J. L. Semmlow and J. Kostis, "Noninvasive characterization of

the sound pattern caused by coronary artery stenosis using FTF/FAEST zero tracking filters:

normal/abnormal study," Ann. Biomed. Eng., vol. 21, pp. 175-182, 03, 1993.

[66] M. Akay, Y. M. Akay, W. Welkowitz, J. L. Semmlow and J. Kostis, "Application of adaptive FTF/FAEST zero tracking filters to noninvasive characterization of the sound pattern caused by coronary artery stenosis before and after angioplasty," Ann. Biomed. Eng., vol. 21, pp. 9-17, 1993.

[67] M. Akay, Y. M. Akay, W. Welkowitz, J. L. Semmlow and J. B. Kostis, "Application of Adaptive Filters to Noninvasive Acoustical Detection of Coronary Occlusions Before and After Angioplasty," Ieee Transactions on Biomedical Engineering, vol. 39, pp. 176-184, 02, 1992.

[68] M. Akay, J. L. Semmlow, W. Welkowitz, M. D. Bauer and J. B. Kostis, "Detection of coronary occlusions using autoregressive modeling of diastolic heart sounds," IEEE Trans. Biomed. Eng., vol.

37, pp. 366-373, Apr, 1990.

[69] M. Akay, J. L. Semmlow, W. Welkowitz, M. D. Bauer and J. B. Kostis, "Noninvasive detection of coronary stenoses before and after angioplasty using eigenvector methods," IEEE Trans. Biomed. Eng., vol. 37, pp. 1095-1104, 11, 1990.

[70] M. Akay and W. Welkowitz, "Acoustical detection of coronary occlusions using neural networks," J.

Biomed. Eng., vol. 15, pp. 469-473, Nov, 1993.

[71] M. Akay, W. Welkowitz, J. L. Semmlow, Y. M. Akay and J. Kostis, "Noninvasive acoustical detection of coronary artery disease using the adaptive line enhancer method," Med. Biol. Eng. Comput., vol. 30, pp. 147-154, 03, 1992.

[72] M. Akay, W. Welkowitz, J. L. Semmlow and J. Kostis, "Application of the ARMA method to acoustic detection of coronary artery disease," Med. Biol. Eng. Comput., vol. 29, pp. 365-372, 07, 1991.

[73] M. Akay, "Automated noninvasive detection of coronary artery disease using wavelet-based neural networks," Artificial Neural Networks in Engineering - Proceedings (ANNIE'94), vol. 4, pp. 517-522, 1994.

[74] Y. M. Akay, M. Akay, W. Welkowitz, S. Lewkowicz and Y. Palti, "Time-frequency analysis of the turbulent sounds caused by femoral artery stenosis in dogs using wavelet transform," in Engineering in Medicine and Biology Society, Proceedings of the Annual International Conference of the IEEE, 1992, pp. 2590-2591.

[75] Y. M. Akay, M. Akay, W. Welkowitz, J. L. Semmlow and J. B. Kostis, "Noninvasive acoustical detection of coronary artery disease: A comparative study of signal processing methods," IEEE Transactions on Biomedical Engineering, vol. 40, pp. 571-578, 1993.

[76] Chen, T.-H., Xing, S.-X., Guo, P.-Y., Yu,Z., "The research of non-invasive method of coronary heart disease based on neural network and heart sound signals," in International Conference on Information Engineering and Computer Science, ICIECS 2009, 2009,.

[77] T. -. Chen, P. -. Guo, S. -. Xing and Y. Zheng, "A new method of sorting of heart sound signal based on wavelet transform and parameter model method," in 4th International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2010, 2010,.

[78] D. Gauthier, Y. M. Akay, R. G. Paden, W. Pavliecek, F. D. Fortuin, J. K. Sweeney, R. W. Lee and M.

Akay, "Spectral analysis of heart sounds associated with coronary occlusions," in Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB, 2008, pp. 49-52.

[79] D. Gauthier, Y. M. Akay, R. G. Paden, W. Pavlicek, F. D. Fortuin, J. K. Sweeney, R. W. Lee and M.

Akay, "Spectral analysis of heart sounds associated with coronary occlusions," in Information Technology Applications in Biomedicine, 2007. ITAB 2007. 6th International Special Topic Conference on, 2007, pp. 49-52.

[80] Güler, I., Kiymik, M.K., Güler,N.F., "Order determination in autoregressive modeling of diastolic heart sounds," J. Med. Syst., vol. 20, pp. 11-17, 1996.

[81] Akay, Metin, Akay, Yasemin M., Welkowitz, Walter, Semmlow, John L., Kostis,John B., "Noninvasive detection of coronary artery disease using neural networks," in IEEE Proceedings of the Annual Conference on Engineering in Medicine and Biology, 1991, pp. 1434-1435.

[82] Akay, Y.M., Akay, M., Welkowitz, W., Kostis,J., "Noninvasive detection of coronary artery disease," IEEE Engineering in Medicine and Biology Magazine, vol. 13, pp. 761-764, 1994.

[83] Akay, Y.M., Akay, M., Welkowitz, W., Lewkowicz, S., Palti,Y., "Dynamics of the sounds caused by partially occluded femoral arteries in dogs," Ann. Biomed. Eng., vol. 22, pp. 493-500, 1994.

[84] Akay, Yasemin M., Akay, Metin, Welkowitz, Walter, Semmlow, John L., Kostis,John B., "A comparative study of advanced signal processing techniques for detection of coronary artery disease," in IEEE Proceedings of the Annual Conference on Engineering in Medicine and Biology, 1991, pp.

2139-2140.



Pages:     | 1 |   ...   | 4 | 5 || 7 | 8 |


Similar works:

«Orthopädische und Sportorthopädische Klinik und Poliklinik der Technischen Universität München Klinikum rechts der Isar (Direktor: Univ.-Prof. Dr. R. Gradinger) Untersuchungen zur Vitalität humaner Chondrosarkomzellen und Chondrozyten, sowie zu biomechanischen und immunhistochemischen Eigenschaften von Knorpelgewebe nach hydrostatischer Hochdruckbehandlung, als neues Verfahren in der Orthopädischen Chirurgie Florian-Dominique Naal Vollständiger Abdruck der von der Fakultät für Medizin...»

«COMMISSIONED OFFICER'S HANDBOOK U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES Program Support Center Human Resources Service Division of Commissioned Personnel 5600 Fishers Lane, Room 4A-15 Rockville, MD 20857-0001 TABLE OF CONTENTS INTRODUCTION......................................................................... 1 RESPONSIBILITIES OF COMMISSIONED CORPS OFFICERS......................... 1...»

«TECHNISCHE UNIVERSITÄT MÜNCHEN FAKULTÄT FÜR MEDIZIN II. Medizinische Klinik und Poliklinik Klinikum rechts der Isar Univ.-Prof. Dr. R. M. Schmid Perkutane transhepatische Cholangiodrainage (PTCD): Indikation, Erfolg, Langzeitverlauf, Komplikationen und deren Risikofaktoren bei Patienten mit benignen und malignen Gallengangstenosen Eine retrospektive Studie über 10 Jahre mit 385 Patienten Simon Christof Nennstiel Vollständiger Abdruck der von der Fakultät für Medizin der Technischen...»

«Int. J. Mol. Sci. 2013, 14, 434-456; doi:10.3390/ijms14010434 OPEN ACCESS International Journal of Molecular Sciences ISSN 1422-0067 www.mdpi.com/journal/ijms Review An Involvement of Oxidative Stress in Endoplasmic Reticulum Stress and Its Associated Diseases Bidur Bhandary 1, Anu Marahatta 1, Hyung-Ryong Kim 2,* and Han-Jung Chae 1,* Department of Pharmacology, School of Medicine, Chonbuk National Univeristy, Jeonju 561-180, South Korea; E-Mails: bidurbhandary@gmail.com (B.B.);...»

«Aus dem Deutschen Rheumaforschungszentrum Berlin DISSERTATION Von der Infektion zur Autoimmunität: Die Bedeutung der Bystander-Aktivierung von Th-Zellen im Modell der experimentellen autoimmunen Enzephalitis Zur Erlangung des akademischen Grades Doctor medicinae (Dr.med.) vorgelegt der Medizinischen Fakultät der Charité Universitätsmedizin Berlin von Volker Siffrin aus Kaiserslautern Dekan: Prof. Dr. med. Martin Paul Gutachter: 1. Prof. Dr. T. Kamradt, Friedrich-Schiller-Universität Jena...»

«2012 Assisted Reproductive Technology Fertility Clinic Success Rates Report National Center for Chronic Disease Prevention and Health Promotion Division of Reproductive Health Updates to this report will be posted on the CDC Web site at the following address: http://www.cdc.gov/art/ART2012 For additional information, send an e-mail to cdcinfo@cdc.gov (Subject: ART) Or write to CDC, ATTN: ART Surveillance and Research Team 4770 Buford Highway, N.E.; Mail Stop F-74; Atlanta, GA 30341-3717....»

«Florida Department of Health, Bureau of Epidemiology ESSENCE User Guide Version 1.0 (Oct. 2010) This should be considered an evolving guide due to the periodic changes made to Florida’s ESSENCE system. It will be updated as necessary, and as resources allow. Aaron Kite-Powell, MS Anita Ofori-Addo, MPH Janet Hamilton, MPH Florida Department of Health Division of Disease Control Bureau of Epidemiology 850-245-4444 TABLE OF CONTENTS INTRODUCTION PURPOSE OVERVIEW LIMITATIONS AND OTHER CONTEXT A....»

«Schönhuth 2005: Eine Frage der Ethik  Eine Frage der Ethik? Die Leitlinien der AG Entwicklungsethnologie1 Michael Schönhuth 1. Wessen Wissenschaft für wen? „Doch stellen Sie sich mal einen Ethnologen vor: Der Mann hat zwei Jahre bei einem fremden Volk gelebt, ist auf die Jagd gegangen, hat Knollen ausgebuddelt, war einsam und vergnügt, hat mit seinen Gastgebern gelacht, geheult, getanzt und geliebt, der Medizinmann hat ihm anvertraut, wie man mit den Feen in den Bergen bumst, und...»

«200/SNEK XXV. GP Stellungnahme zu Enquete-Kommission Würde am Ende des Lebens 1 von 6 Sehr geehrte Damen und Herren! Im Zusammenhang mit der derzeit laufenden Sterbehilfe-Debatte darf ich Ihnen die Stellungnahme der Arbeitsgruppe Ethik der Österreichischen Gesellschaft für Anästhesie, Reanimation und Intensivmedizin übermitteln, die am 13.4.2014 veröffentlicht wurde und damals bereits Mag. Aubauer sowie den den Parlamentsklubs zugegangen ist. Sie ist zudem auf der Aktuell-Seite der...»

«An Oracle White Paper Updated September 2012 Using Oracle GoldenGate 11g for Oracle Database Using Oracle GoldenGate 11g for Oracle Database Executive Overview Introduction Architecture Overview Oracle GoldenGate Capture Oracle GoldenGate Trail Files Oracle GoldenGate Delivery Oracle GoldenGate Manager Associated Products One Platform, Many Solutions Zero Downtime Migrations and Upgrades Query Offloading Disaster Recovery and Data Protection Active-Active Database Replication Operational...»





 
<<  HOME   |    CONTACTS
2016 www.book.dislib.info - Free e-library - Books, dissertations, abstract

Materials of this site are available for review, all rights belong to their respective owners.
If you do not agree with the fact that your material is placed on this site, please, email us, we will within 1-2 business days delete him.